P0562System Voltage Low
What it means
The supply voltage the ECU sees is below the minimum, usually under about 10–11 V with the engine running.
Symptoms
- Battery light on
- Hard starting
- Several modules storing communication codes
Common causes
- Weak or discharged battery
- Failing alternator or regulator
- Slipping drive belt
- Poor ground or high-resistance cable
What to check first
- Load-test the battery
- Check charging voltage (about 13.5–14.7 V)
- Voltage-drop test the main grounds
Generic OBD-II meaning. Manufacturer-specific meanings and checks can differ; always check the service information for the car.